Misc. Values: Wirepaths
Use this page to enter values for custom parameters that have been defined for the current post processor. You can set values for up to 20 miscellaneous values: 10 reals (mr1-mr10) and 10 integers (mi1-mi10). The default values, the text labels, and how the post processor formats and uses these values is unique to each post processor. The default values and text are set in the control definition.
- Mastercam writes the miscellaneous values to the NCI file at the beginning of each operation and links each value to the appropriate variable when you run the post processor.
- Use the Misc Int/Real page in the Control Definition Manager to manage the default values and behavior. The exact appearance of this dialog and the fields that it displays vary depending on the selected machine.
Primary cut / Taper cut
Choose Primary cut to set the miscellaneous values for the primary cut and Taper cut to set the miscellaneous values for the taper cut. Available only when using a TECH power library.
Pass
Sets the pass number to which you want to assign miscellaneous values.
Integers
Sets the value of an integer variable (mi1-mi10) in the post processor. Integers are whole numbers such as 3, 50, or 764 and are used for counting or numbering. Enter values directly in each field. The values are stored with the operation.
Reals
Sets the value of a real number variable (mr1-mr10) in the post processor. Real numbers are represented by a whole number and fraction such as 1.25 and are used for storing measurements and other values to some limit of precision. Enter values directly in each field. The values are stored with the operation.
Active Field
Sets the currently highlighted miscellaneous real or integer to all passes in the library.
All fields
Applies all the values to all passes in the library.
Automatically set to post values when posting
Choose this checkbox when posting to disable all the Real and Integer fields on this page. Mastercam will disregard all the information from this dialog and will read the values from the post. This lets you use updated values whenever your post changes without needing to edit each operation. No values are stored with the operation.
Set to post values
Reads the default values stored in the post processor file. You can edit or override the default values by entering new values here. The values are stored with the operation.
Set to Op Defaults
Reads the default values stored in the .mcam-defaults file. You can edit or override the default values by entering new values here. The values are stored with the operation.