Wire/Power: POWER
Mastercam Wire uses two types of power settings libraries. This topic covers the type of libraries with the .POWER extension. For information on the .TECH power libraries, see Wire/Power: TECH.
Use this page to choose a wire power settings library file and use its values for the wirepath operation. By default, the power settings library file is associated with the operation as an external file. The settings that display in this page reflect the most recent version of the associated power library file in its saved location.
You can also set the pass number to use for the first pass of the wirepath, and specify the settings for a single pass. Each pass can have unique settings. Up to 24 passes can be stored in a single library file. In Mastercam Wire, pass refers to a single path made by the wire around a contour. Pass is synonymous with cut. Each pass can be saved with unique power settings needed to cut a certain material type on a certain wire EDM machine. For example, Pass 1 in the library may correspond to a rough cut, Pass 2 a tab cut, and Passes 3 - 5 finish cuts, also known as skim cuts.
- Because the power settings library file is associated with the operation as an external file, the fields you use to edit the power settings for each pass are unavailable unless you have disassociated the wirepath from the power settings library by deselecting Associate to library. Using this method allows you to create unique power library settings that are saved only with the wirepath operation in the Mastercam part file.
- Stock to leave and Apply additional offset to apply to the entire operation rather than a single pass. Therefore, these two options will always be available, whether or not you have selected Associate to library .
- Applying Stock to leave settings may require post customization.
- To convert a power library from a previous version of Mastercam, simply change the file extension to .power in Windows Explorer before accessing it from Mastercam.
Power library
Read-only. Displays the active power library, including its location.
Edit library
Opens the Edit Library dialog box so that you can make changes to the power settings. The changes apply to all operations in the current part file that are associated with the library. The changes also apply to any previously saved part files where operations are associated with the same library file.
Open
Opens the Edit Library dialog box where you can click Select Library to choose and load a power library.
Save
Saves power settings to the library file you define.
Associate to library
Enables associativity to a power settings library file (.power). If the associated library file has changed since the operating was created, when you next open the Mastercam part file that the changes require the operation to be regenerated. When disabled, the power settings library is not associated to the wirepath. When first creating the wirepath, Mastercam Wire reads the power settings from the library but allows them to be changed for the current operation. When editing the wirepath, Mastercam Wire retains the power settings that you set.
Starting pass #
Choose the pass number to use for the first pass of the wirepath.
Wire
When checked, wire is threaded. Typically remains enabled.
Power
When checked, applies voltage to the wire. Typically remains enabled.
Fill tank
The initial state for the fluid tank where on means full.
Pass #
Enter the pass number to edit the settings for a single pass in the current library. Each pass can have unique settings. Up to 24 passes can be stored in a single library file.
Offset
The wire offset register number. You may need to refer to your wire machine documentation for this information.
Condition code
A wire machine-specific value that corresponds to a register number. Refer to your wire machine documentation for condition codes for material and wire type and thickness.
Feed rate
Most EDMs do not use a feed rate. However, this value is available if needed by the control.
Wire diameter
Works in conjunction with the wire radius parameter and is automatically updated when a wire radius is entered.
Wire radius
Works in conjunction with the wire diameter parameter and is automatically updated when a wire diameter is entered.
Wire overburn
The amount of material beyond the wire diameter that can be removed.
Stock to leave
The amount of stock to leave for all passes. Stock to leave offsets the wire in the direction specified by the Compensation Direction. Stock to leave and Apply additional offset to apply to the entire operation rather than a single pass. Therefore, these two options will always be available, whether or not you have selected Associate to library.
Total offset
Read-only. Sum of the wire radius, overburn, and stock to leave.
Pass comment
Information about the power settings for the current pass number. For example, the Pass 1 settings could be commented as Rough Cut for a certain material type and thickness.