Wire/Power: TECH
Mastercam Wire uses two types of power settings libraries. This topic covers the .TECH power libraries. For information on power libraries with the .POWER extension, see Wire/Power: POWER.
Use this page to choose a wire TECH power settings library file and use its values for the wirepath operation. This page pertains to any machine group based on a machine definition where the controller uses a TECH library, such as Makino or Mitsubishi.
A TECH library is usually organized into 9 passes. In Mastercam Wire, pass refers to a single path made by the wire around a contour. Pass is synonymous with cut. The first pass is usually the rough pass, and the rest are finish passes. The exception is contour wirepaths that have a taper cut with a land. These types of wirepaths can have up to 18 passes; nine for the primary cut, and nine for the tapered cut.
TECH power libraries are not associated to wirepaths. When first creating a wirepath, Mastercam Wire reads the power settings from the library but allows them to be changed for the current operation. When editing the wirepath, Mastercam Wire retains the power settings that you set. Default TECH libraries are set up in the Files and Control Model pages of the Control Definition Manager.
Use the Wire/Power, TECH dialog box to:
- Choose a different TECH power library for the current operation or edit some of the current library settings by using the TECH buttons to open the Technology database.
- Edit power library values in the tables for both the primary cut and taper cuts.
- Establish the starting pass for the operation.
- Apply wire, power, and coolant options.
- Set the stock to leave value for the wirepath.
Technology library
Displays the selected library for the current operation.
Tech
Opens the Technology database dialog box where you can select options from the current power library to define the wirepath parameters.
Primary / Taper cut tables
Displays the power, offset, feed, and register library settings for the current operation and each of its passes. Click on a cell and type in a different value to change values for any pass or related setting.
Taper Cut
Activates Taper cut tech. This is only available for tapered Contour wirepaths with a land.
Wire
When checked, wire is threaded. Typically remains enabled.
Power
When checked, applies voltage to the wire. Typically remains enabled.
Fill tank
The initial state for the fluid tank; on means full.
Starting pass
Choose the pass that you want to set as the starting pass for the operation. You can choose the rough pass, or any one of the skim passes.
Stock to leave
The amount of stock to leave for all passes. Stock to leave offsets the wire in the direction specified by the Compensation direction.
Apply additional offset to
Program coordinates and Machine offset register determine how Stock to leave is applied to a wirepath. The defaults for these options are set in the Stock to leave application section of the Cutter compensation page in the Control Definition.